Agilent 86120A Wavelength Meter Calibration and Repair Services
Agilent HP 86120A Wavelength Meter Calibration and Repair Services. We take care of E14, E7 and E4 errors that will soon or later appear on your equipment.
The most common error on the 86120 series is E14 which means the internal reference laser is out of service. Other errors often seen on 86120A is Error 7 (E7) Motor not settled which appears on the wavelength meter when it cannot control the motor to move the mirror inside the instrument correctly.
Send your unit to our Lab for a motor repair or a motor replacement and a full evaluation of the condition of your Agilent 86120A. After repair, your wavelength meter will return back to you fully calibrated with calibration data. Ask us about our full refurbish process which, once performed, will include a one year warranty on the complete unit; not just the laser.
Here is the list of all error messages on this model:
- E1 ERROR 1 BAD CHECKSUM FROM MOTOR
- E2 ERROR 2 MOTOR COMMUNICATION PROBLEM
- E3 ERROR 3 MOTOR NOT MOVING
- E4 ERROR 4 MOTOR INDEX PULSE NOT FOUND
- E5 ERROR 5 MOTOR CHIP SET INIT FAILED
- E6 ERROR 6 MOTOR COMMUTATION FAILURE
- E7 ERROR 7 MOTOR NOT SETTLED
- E8 ERROR 8 MOTOR DID NOT STOP
- E9 ERROR 9 MOTOR MOTION ERROR
- E10 ERROR 10 MOTOR POSITION LIMIT FAILED
- E11 ERROR 11 MOTOR POSITION WRAP FAILED
- E12 ERROR 12 POWER LEVEL TOO HIGH
- E13 ERROR 13 DATA DOWNLOAD PROBLEM
- E14 ERROR 14 DATA ACQUISITION PROBLEM
- E15 ERROR 15 MAX NUMBER OF SIGNALS FOUND
- E16 ERROR 16 MOTOR INTERRUPT RECEIVED
- E17 ERROR 17 ROM BYTE UNERASED
- E18 ERROR 18 ROM WRITE OPERATION FAILED
- E19 ERROR 19 ROM DEFECTIVE
- E20 ERROR 20 ROM DATA INVALID
- E21 ERROR 21 ROM VERSION INCOMPATIBLE
- E22 ERROR 22 ROM POLLING LIMITED OUT
- E23 ERROR 23 INPUT OUT OF RANGE
- E24 ERROR 24 BAD CAL ROM DATA
- E25 ERROR 25 BAD CAL ROM DATA
- E26 ERROR 26 BAD CAL ROM DATA
- E27 ERROR 27 BAD CAL ROM DATA
- E28 ERROR 28 BAD CAL ROM DATA
- E29 ERROR 29 BAD CAL ROM DATA
- E30 ERROR 30 NVSRAM WRITE OPERATION FAILED
- E31 ERROR 31 SOFTWARE INITIALIZATION FAIL
- E32 ERROR 32 HARDWARE INITIALIZATION FAIL
- E33 ERROR 33 INITIALIZATION TIMEOUT
- E34 ERROR 34 BATTERY FAILED
- E36 ERROR 36 TOO MANY ERRORS
- E37 ERROR 37 FUNCTION NOT YET IMPLEMENTED
- E38 ERROR 38 PRINTER OFF LINE
- E39 ERROR 39 PRINTER OUT OF PAPER
- E40 ERROR 40 PRINTER ERROR DETECTED
- E41 ERROR 41 PRINTER TIMED OUT
- E42 ERROR 42 PRINTOUT WAS ABORTED
- E43 ERROR 43 NOT ALLOWED IN FABRY PEROT
- E44 ERROR 44 NOT ALLOWED IN S/N
- E45 ERROR 45 UNKNOWN KEYPRESS
- E46 ERROR 46 NUM LINES < NUM REFS
- E47 ERROR 47 NUM LINES > NUM REFS
- E48 ERROR 48 NO REFERENCE SIGNAL
- E49 ERROR 49 GAIN RANGING ERROR
- E50 ERROR 50 INCOMPATIBLE HARDWARE
- E51 ERROR 51 UNKNOWN ERROR