Jonard OFI-100 Advanced Optical Fiber Identifier w/ Power Meter & VFL

The Jonard OFI-100 Advanced Optical Fiber Identifier detects optical traffic direction, relative core power and modulated signals without interrupting the network. Its colour LCD displays signal direction, frequency and battery status, while the built-in optical power meter and visual fault locator provide additional testing capabilities. A reversible adapter supports 250 µm, 900 µm, 2 mm and 3 mm fibers, making this Jonard instrument suitable for installation, identification and troubleshooting.

Download the Jonard OFI-100 Advanced Optical Fiber Identifier w/ Power Meter & VFL Specification Sheet (PDF) Download the Jonard OFI-100 Advanced Optical Fiber Identifier w/ Power Meter & VFL Specification Sheet (PDF)

Read moreShow less
Reference:
OFI-100
Brand:
Add to compare0
Description

Jonard OFI-100 Advanced Optical Fiber Identifier with Optical Power Meter and Visual Fault Locator

The Jonard OFI-100 Advanced Optical Fiber Identifier is a portable fiber optic testing instrument designed to identify optical traffic direction and display relative core power without damaging the fiber or disrupting network operation. It combines an advanced fiber identifier, optical power meter and visual fault locator in one convenient tool for fiber installation, maintenance and troubleshooting.

The OFI-100 helps technicians determine whether an optical fiber is carrying a signal before performing maintenance or disconnection procedures. It can identify continuous-wave signals and modulated tones at 270 Hz, 1 kHz and 2 kHz. An audible warning alerts the technician when compatible traffic is detected, while the colour LCD displays the signal direction, relative core power, detected frequency and remaining battery status.

A reversible adapter expands the instrument’s compatibility across several common fiber sizes. One side accommodates 2 mm and 3 mm fiber optic cables, while the opposite side supports 250 µm bare fiber and 900 µm buffered fiber. Built-in optical power meter and visual fault locator ports provide additional functions without requiring separate handheld instruments for basic testing.

Features and Benefits of the Jonard OFI-100

  • Identifies optical traffic without interrupting normal network operation.
  • Displays the direction in which light is travelling through the fiber.
  • Measures and displays relative optical core power.
  • Detects continuous-wave and modulated optical signals.
  • Identifies 270 Hz, 1 kHz and 2 kHz test tones.
  • Provides an audible warning when compatible optical traffic is detected.
  • Colour LCD displays traffic direction, signal frequency and battery life.
  • Built-in optical power meter supports convenient optical measurements.
  • Built-in visual fault locator supports continuity checking and fault location.
  • Reversible adapter accommodates 250 µm, 900 µm, 2 mm and 3 mm fibers.
  • 800 to 1700 nm identification wavelength range.
  • InGaAs detector supports measurements across common telecommunications wavelengths.
  • Protective rubber sleeve helps protect the instrument from accidental drops.
  • Powered by two readily available AA batteries.
  • Supplied with an adapter, batteries and carrying pouch.

Non-Intrusive Optical Traffic Identification

The primary function of the Jonard OFI-100 is to determine whether an optical fiber is carrying traffic and identify the direction of that traffic without disconnecting or cutting the fiber. This capability is valuable when technicians are working with active network infrastructure and need additional information before beginning maintenance.

The fiber is positioned in the appropriate adapter channel, and the instrument detects light present in the fiber. The colour display indicates the direction of the optical signal and provides a relative core-power reading. This information helps technicians distinguish active fibers from inactive fibers and understand the direction in which the detected signal is travelling.

As with any fiber identification procedure, the correct adapter channel must be used for the fiber diameter and construction. The fiber should be clean, undamaged and positioned according to the manufacturer’s operating instructions.

Modulated Signal and Tone Detection

The OFI-100 identifies continuous-wave signals as well as modulated signals at 270 Hz, 1 kHz and 2 kHz. These standard test tones are commonly used during fiber identification and tracing procedures.

When a compatible modulated signal is detected, the instrument displays the identified frequency and provides an audible warning. This allows one technician to introduce a selected tone at one end of a link while another technician identifies the corresponding fiber at a remote location.

Clear Colour Display

The integrated LCD presents the information required during a fiber identification procedure in an easy-to-read format. The display indicates relative core power, optical signal direction, detected modulation frequency and battery status.

A visual direction indicator helps technicians quickly understand whether light is travelling from left to right or from right to left through the instrument. The battery indicator also allows the technician to monitor the two AA batteries before beginning field testing.

Reversible Fiber Adapter

The Jonard OFI-100 includes a reversible adapter for four common fiber and cable sizes. One side supports 2 mm and 3 mm jacketed fiber optic cables, while the opposite side supports 250 µm bare fiber and 900 µm buffered fiber.

Selecting the correct adapter position is important for obtaining a valid identification result and avoiding unnecessary pressure on the fiber. The technician should confirm the fiber diameter before placing the cable into the instrument. The adapter and contact surfaces should also be kept clean to support repeatable operation.

Built-In Optical Power Meter

The built-in optical power meter provides additional measurement capability for fiber installation and maintenance. Technicians can use this function to evaluate optical signal levels without relying on a separate power meter for basic field measurements.

The appropriate wavelength, connector interface and measurement procedure should be selected before testing. Optical connectors must be inspected and cleaned before connection because contamination can affect measurement results and may damage the connected interfaces.

Built-In Visual Fault Locator

The integrated visual fault locator uses a Class 3R laser diode with a stated output range from 1 to 5 mW. Visible red light can assist with continuity verification and the location of certain breaks, excessive bends or poor connections in compatible fiber links.

The visual fault locator should only be activated after the fiber path and connector have been checked. Never look directly into the VFL port, an active connector or the end of a connected fiber. Suitable laser safety procedures must be followed whenever the visual fault locator is operating.

Durable Portable Design

The OFI-100 is protected by a rubber sleeve that helps reduce damage from accidental drops and everyday field handling. Its compact dimensions and weight of approximately 268 g make it convenient to carry during fiber installation and maintenance work.

The instrument operates using two AA batteries, allowing technicians to replace the power source without requiring a dedicated charger. An included carrying pouch protects the instrument, reversible adapter and related accessories during transportation and storage.

Jonard OFI-100 Applications

  • Identification of active optical fibers
  • Determination of optical traffic direction
  • Relative optical core-power measurement
  • Detection of continuous-wave optical signals
  • Identification of 270 Hz, 1 kHz and 2 kHz test tones
  • Live fiber network maintenance
  • Fiber continuity verification
  • Visual fault location
  • Optical power measurement
  • FTTx installation and troubleshooting
  • Telecommunications network maintenance
  • Data centre fiber identification
  • Fiber optic contractor field testing

Jonard OFI-100 Technical Specifications

Specification Details
Manufacturer Jonard Tools
Model OFI-100
Product Type Advanced Optical Fiber Identifier with Optical Power Meter and Visual Fault Locator
Identification Wavelength Range 800 to 1700 nm
Identified Signal Types CW, 270 Hz ±5%, 1 kHz ±5% and 2 kHz ±5%
Signal Frequency Display 270 Hz, 1 kHz and 2 kHz
Detector Type 1 mm InGaAs detector
Supported Fiber Sizes 250 µm, 900 µm, 2 mm and 3 mm
Signal Direction Indication Colour display
Signal Direction Test Range at 1310 nm -46 to +10 dBm, CW, 900 µm fiber
Signal Direction Test Range at 1550 nm -50 to +10 dBm, CW, 900 µm fiber
Insertion Loss for 250 µm and 900 µm Fiber 1.0 dB
Insertion Loss for 2 mm and 3 mm Cable 1.5 dB
Visual Fault Locator Class 3R laser diode, 1 to 5 mW
Battery Type Two AA batteries
Dimensions 23.5 × 4.29 × 5 cm
Weight Approximately 267.86 g
UPC 810053351529

Included Accessories

  • Jonard OFI-100 Advanced Optical Fiber Identifier
  • Reversible adapter for 250 µm, 900 µm, 2 mm and 3 mm fibers
  • Two AA batteries
  • Protective carrying pouch

Operational notice: Fiber identification results may be affected by fiber construction, jacket material, optical power, wavelength, adapter selection and instrument positioning. Select the correct adapter channel and follow the manufacturer’s operating instructions before testing.

Laser safety notice: Never look directly into the visual fault locator port, an active optical connector or the end of a connected fiber. Follow applicable laser safety procedures whenever the visual fault locator or another optical source is active.

The Jonard OFI-100 Advanced Optical Fiber Identifier provides a convenient combination of traffic identification, direction detection, relative core-power measurement, optical power testing and visual fault location. Its reversible adapter, clear colour display and compact protected enclosure make it a practical tool for professional fiber installation, maintenance and troubleshooting.