Anritsu MS9710C Optical Spectrum Analyzer OSA Repair and Calibration Services

Simbol Test Systems provides professional in-lab Anritsu MS9710C Optical Spectrum Analyzer repair and calibration services to help maintain accurate, reliable performance for your optical test and measurement equipment. The Anritsu MS9710C is a diffraction-grating optical spectrum analyzer designed for analysis across the 600 to 1750 nm wavelength range, and Simbol has been servicing this model for over 15 years.

Our premium calibration process is designed to help ensure the MS9710C OSA meets or exceeds published manufacturer specifications. Calibration may include verification of optical alignment, wavelength calibration with internal cell, wavelength accuracy with external source, wavelength resolution accuracy, wavelength linearity, dynamic range, level accuracy, level flatness, power linearity, polarization dependency, stability, return loss, and reference output power.

Following calibration, your equipment may be returned with a calibration label, calibration certificate, and related calibration data, including before-and-after results where applicable. If the unit does not successfully complete calibration, we can evaluate the repair requirements and provide a repair quotation for approval before proceeding. Some MS9710C units are known to suffer from encoder-related defects that may not always be repairable due to limited parts availability.

Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council).

Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation.

Anritsu MS9710C Optical Spectrum Analyzer Specifications PDF Download Anritsu MS9710C Optical Spectrum Analyzer Specifications (PDF)

Anritsu MS9710C Optical Spectrum Analyzer Operation Manual PDF Download Anritsu MS9710C Optical Spectrum Analyzer Operation Manual (PDF)

Read moreShow less
Reference:
MS9710C_SER
Brand:
Add to compare0
Description

Anritsu MS9710C Optical Spectrum Analyzer – Repair and Calibration Services

The Anritsu MS9710C Optical Spectrum Analyzer is a widely used instrument in telecom, R&D, and production environments. As these units age, proper calibration and maintenance become essential to ensure wavelength accuracy, power stability, and long‑term reliability. Simbol provides complete repair and calibration services for the MS9710C, following strict OEM specifications and industry‑standard procedures.

Premium MS9710C Calibration Services

Every MS9710C sent to Simbol undergoes a full, traceable calibration designed to ensure the instrument meets or exceeds the manufacturer’s published specifications. Your unit will be returned with a calibration sticker, calibration certificate, and a complete set of before‑and‑after calibration data (3 pages of measurement results).

Calibration Items Included

  • Optical Alignment
  • Wavelength Calibration with Internal Cell
  • Wavelength Accuracy Calibration (External Source)
  • Wavelength Resolution Accuracy
  • Wavelength Linearity
  • Dynamic Range Verification
  • Level Accuracy
  • Level Flatness
  • Power Linearity
  • Polarization Dependency
  • Stability (Power and Wavelength)
  • Return Loss
  • Reference Output Power

Traceability

All calibration work is performed using instrumentation traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council), ensuring full measurement traceability and compliance.

MS9710C Repair and Adjustment

The Anritsu MS9710C is known to suffer from encoder‑related defects due to the unavailability of the custom encoder part originally manufactured exclusively for Anritsu. When these components fail, repair feasibility depends on the specific failure mode and the condition of the remaining internal assemblies.

If your MS9710C does not pass calibration, Simbol will provide a detailed repair quotation—assuming the required repair is possible. After repairs are completed, your OSA is fully recalibrated to ensure it meets OEM performance standards and is returned in verified working condition.

Why Choose Simbol?

  • Specialized expertise with Anritsu OSAs
  • Premium, traceable calibration procedures
  • Fast turnaround and detailed documentation
  • Reliable repair capability for aging instruments
  • Full calibration data included with every service

Maintain the accuracy and performance of your Anritsu MS9710C Optical Spectrum Analyzer with Simbol’s trusted calibration and repair services. Contact us today for a diagnostic evaluation or service quote.