Click for more products.
No products were found.
Simbol Test Systems provides professional in-lab Agilent Keysight N7752A calibration and repair services to help maintain accurate, reliable performance for your optical test and measurement equipment. The N7752A is a dual-application instrument featuring 2 singlemode attenuator ports and 2 power meter ports, and all calibration services are performed in our laboratory using documented procedures, traceable standards, and experienced technical staff.
Simbol performs a premium calibration on the Agilent Keysight N7752A, meaning that key specifications are tested in detail rather than only at a few wavelengths or power levels. Our process is designed to evaluate important performance characteristics such as linearity, repeatability, attenuation accuracy, and power meter response across multiple wavelengths and power levels. This helps verify real operating performance for both the attenuator and power meter sections of the instrument.
Following calibration, your equipment may be returned with a calibration label, calibration certificate, and related calibration data. If the unit does not successfully complete calibration, we can evaluate the repair requirements and provide a repair quotation for approval before proceeding. Simbol also has troubleshooting and repair capability for faulty or broken units.
Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council).
Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation.
The Agilent/Keysight N7752A is a dual‑function instrument combining a precision optical attenuator with an integrated power meter. Because both functions directly affect measurement accuracy, proper calibration requires far more than a quick check at two wavelengths and two power levels. Many laboratories perform only minimal testing, which is insufficient for an instrument as sensitive and complex as the N7752A.
Optical attenuators and power meters often develop linearity issues over time. This means:
Because the N7752A calculates attenuation based on incoming power, any drift in detector sensitivity or attenuator linearity can lead to significant measurement errors. A proper calibration must verify performance across multiple wavelengths, power levels, and attenuation points. Simbol performs all of these checks—thoroughly.
Every N7752A sent to Simbol undergoes a complete, traceable calibration process that includes:
Your instrument is returned with:
If your attenuator or power meter fails calibration due to internal faults, Simbol provides expert repair services. Our technicians will:
Ensure the accuracy and reliability of your Agilent Keysight N7752A Dual Application Attenuator and Power Meter with Simbol’s professional calibration and repair services. Contact us today for a diagnostic evaluation or service quote.
Please sign in first.
Sign in