Ando Yokogawa AQ6317B Optical Spectrum Analyzer OSA Repair and Calibration Services

Simbol Test Systems provides professional in-lab Ando Yokogawa AQ6317B Optical Spectrum Analyzer repair and calibration services to help maintain accurate, reliable performance for your optical test and measurement equipment. All calibration services are performed in our laboratory using documented procedures, traceable standards, and experienced technical staff.

Our experience with Ando optical spectrum analyzers, now part of the Yokogawa family, dates back to 2000 through technical collaboration with Ando. For the AQ6317B OSA, Simbol has developed custom software to support automated calibration testing and update results directly in the instrument calibration tables where applicable. This process is designed to provide a more complete verification than a basic limited report.

Following calibration, your equipment may be returned with a calibration label, calibration certificate, and related calibration data. If the unit does not successfully complete calibration, we can evaluate the repair requirements and provide a repair quotation for approval before proceeding.

Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council).

Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation for your Ando Yokogawa AQ6317B Optical Spectrum Analyzer.

Ando Yokogawa AQ6317B Optical Spectrum Analyzer Specification Sheet PDF Download Ando Yokogawa AQ6317B Optical Spectrum Analyzer Specification Sheet (PDF)

Ando Yokogawa AQ6317B Optical Spectrum Analyzer User Manual PDF Download Ando Yokogawa AQ6317B Optical Spectrum Analyzer User Manual (PDF)

Read moreShow less
Reference:
AQ6317B_SER
Brand:
Add to compare0
Description

Ando Yokogawa AQ6317B Optical Spectrum Analyzer – Repair and Calibration Services

The Ando/Yokogawa AQ6317B Optical Spectrum Analyzer is a high‑performance OSA widely used in telecom, R&D, and production environments. As these instruments age, proper calibration and maintenance are essential to ensure wavelength accuracy, power stability, and long‑term reliability. Simbol provides complete repair and calibration services for the AQ6317B, following strict OEM specifications and industry‑standard procedures.

Ando AQ6317B Calibration Services

Every AQ6317B sent to Simbol undergoes a premium, traceable calibration designed to ensure the OSA meets or exceeds the manufacturer’s published specifications. Your unit will be returned with a calibration sticker, calibration certificate, and a full set of before‑and‑after calibration data (9 pages of measurement results).

Calibration Items Included

  • Optical Alignment
  • Wavelength Calibration with Internal Cell
  • Wavelength Accuracy Calibration (External Source)
  • Wavelength Resolution Accuracy
  • Wavelength Reproducibility
  • Wavelength Linearity
  • Level Accuracy
  • Level Flatness
  • Level Response
  • Waveform Symmetry, Flatness and Ripple
  • Stability (Wavelength and Power)
  • Polarization Dependency
  • Dynamic Range Verification
  • Power Linearity

Traceability

All calibration work is performed using instrumentation traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council), ensuring full measurement traceability and compliance.

AQ6317B Repair and Mechanical Adjustment

If your AQ6317B does not pass calibration, Simbol provides complete repair services. We are the only independent laboratory in North America with the capability to mechanically realign Ando/Yokogawa monochromators, a critical procedure for restoring wavelength accuracy and optical performance.

After repairs are completed, your OSA is fully recalibrated to ensure it meets OEM performance standards and is returned in verified working condition.

Why Choose Simbol?

  • Specialized expertise with Ando/Yokogawa OSAs
  • Premium, traceable calibration procedures
  • Unique capability to realign monochromators
  • Fast turnaround and detailed documentation
  • Reliable repair capability for aging instruments

Maintain the accuracy and performance of your Ando Yokogawa AQ6317B Optical Spectrum Analyzer with Simbol’s trusted calibration and repair services. Contact us today for a diagnostic evaluation or service quote.

Read moreShow less
Product Details
AQ6317B_SER

Menu

Share

Cookie consent