Ando Yokogawa AQ6315E Optical Spectrum Analyzer Repair and Calibration Services
Simbol Test Systems Inc. provides professional in-lab Ando AQ6315E Optical Spectrum Analyzer repair and calibration services for customers who require accurate and reliable performance from their optical test equipment. We have in-depth experience troubleshooting the AQ6315E OSA and can service both hardware and firmware related faults.
Our repair capabilities for the Ando Yokogawa AQ6315E include defective board repair, chopper motor repair or replacement, monochromator adjustment, and RF module repair or replacement. We can also troubleshoot and resolve a wide range of error codes and error messages affecting instrument operation and measurement performance.
All calibration services are performed in our laboratory using documented procedures, traceable standards, and experienced technical staff. Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council).
Following service, your equipment may be returned with a calibration label, calibration certificate, and related calibration data. If the unit does not successfully complete calibration, we can evaluate the repair requirements and provide a repair quotation for approval before proceeding.
Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation for your Ando Yokogawa AQ6315E Optical Spectrum Analyzer.
Download Ando Yokogawa AQ6315E Optical Spectrum Analyzer Specifications (PDF)
Ando / Yokogawa AQ6315E Optical Spectrum Analyzer – Evaluation, Calibration & Repair Services
AQ6315E Evaluation: Send your unit to our laboratory for a complete diagnostic evaluation. Once the evaluation is completed, you will receive a detailed report including our findings and recommendations. In many cases, a calibration with updated calibration tables is sufficient; however, if repairs are required, we will provide a formal repair quotation. No work is performed until we receive your approval.
After repair, your AQ6315E Optical Spectrum Analyzer will be returned fully calibrated with all pertinent calibration data. The AQ6315E is now a rare and highly sought‑after OSA capable of measuring in the visible range, making it a valuable instrument worth maintaining and restoring.
Premium AQ6315E Calibration
Our premium calibration ensures that your AQ6315E meets or exceeds the manufacturer’s published specifications. Your instrument will be returned with a calibration sticker, calibration certificate, and complete calibration data—including both pre‑calibration and post‑calibration results (7 pages of data).
Calibration Items Included:
- Optical Alignment
- Wavelength Calibration with Internal Cell
- Wavelength Accuracy Calibration
- Wavelength Resolution Accuracy
- Wavelength Reproducibility
- Dynamic Range
- Level Accuracy
- Level Flatness
- Level Response
- Waveform Symmetry, Flatness and Ripple
- Stability
Traceability
All instrumentation used during calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council), ensuring full measurement traceability.
AQ6315E Repair or Adjustment
Simbol is the only independent laboratory in North America with the capability to mechanically realign Ando/Yokogawa monochromators. If your unit does not pass calibration, we will provide a complete repair quotation and restore your OSA to full working condition.