Agilent 86142B Optical Spectrum Analyzer Calibration and Repair Services

Simbol Test Systems Inc. provides professional Agilent 86142B Optical Spectrum Analyzer calibration and repair services for customers who require accurate and reliable performance from their optical test equipment. We specialize in the repair of optical spectrum analyzers (OSA), tunable laser sources (TLS), and wavelength meters.

We have experience servicing the Agilent 86142B OSA, including troubleshooting and repair of the common Error 20002 fault. On the 86142B, this error indicates a problem in the slot positioning system, typically involving the motor that controls the resolution bandwidth slit wheel. When this fault occurs, the instrument may no longer operate correctly and measurement accuracy may be affected.

All calibration services are performed in our laboratory using documented procedures, traceable standards, and experienced technical staff. Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council). Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation.

Read moreShow less
Reference:
86142B_SER
Brand:
Add to compare0
Description

Agilent / HP 86142B Optical Spectrum Analyzer – Calibration & Repair Services

Send your Agilent 86142B Optical Spectrum Analyzer to our laboratory for a complete diagnostic evaluation, including motor repair or replacement, optical alignment verification, and subsystem testing. After repair, your OSA is returned fully calibrated with complete calibration data and a calibration report, ensuring the instrument meets its original performance specifications.


Agilent 86142B Errors That Require Mandatory Repair

The 86142B OSA may display critical system errors when internal components such as the ADC subsystem, grating positioning system, or calibration memory become unstable or fail. Our technicians are trained to diagnose and repair all known 86142B error codes, restoring full instrument functionality.

  • 86142B Error 20001 – Error detected in ADC sub-system
  • 86142B Error 20003 – Error detected in grating positioning system
  • 86142B Error 20004 – Monochromator calibration data is invalid
  • 86142B Error 20005 – Trans-impedance calibration data is invalid
  • 86142B Error 20006 – Monochromator flatness calibration data is invalid
  • 86142B Error 20007 – Sweep timeout
  • 86142B Error 30000 – Internal communications error
  • 86142B Error 30001 – Auto-Measure software error

What You Receive After Calibration

Your Agilent 86142B will be returned with:

  • A calibration label with date and due date
  • A full calibration certificate
  • All calibration data and measurement results

If the unit cannot be successfully calibrated due to a hardware fault, we will:

  • Perform a complete diagnostic evaluation
  • Provide a repair quotation for your approval
  • Complete the repair and recalibration once approved

Your equipment is returned in verified working condition, ready for use in production, laboratory, or field environments.

Read moreShow less
Product Details
86142B_SER

Menu

Share

Cookie consent