HP Agilent 86120B Multi Wavelength Meter Repair and Calibration Services
Simbol Test Systems provides professional in-lab HP Agilent 86120B Multi Wavelength Meter repair and calibration services to help maintain accurate, reliable performance for your optical test equipment. All calibration services are performed in our laboratory using documented procedures, traceable standards, and experienced technical staff.
We have experience servicing the Agilent 86120B Multi Wavelength Meter, including troubleshooting and repair of Error 14 (E14) data acquisition faults. On the 86120B, Error 14 typically appears when the unit cannot detect the internal HeNe laser during self-test, often due to laser aging. In many cases, the appropriate corrective action is HeNe laser replacement followed by a full evaluation of the instrument.
Following calibration, your equipment may be returned with a calibration label, calibration certificate, and related calibration data. If the unit does not successfully complete calibration, we can evaluate the repair requirements and provide a repair quotation for approval before proceeding.
Traceability: Instrumentation used during this calibration is traceable to N.I.S.T. (National Institute of Standards and Technology) or C.N.R.C. (Canadian National Research Council).
Contact us with your model number and a brief description of the issue to request a calibration quote or repair evaluation for your HP Agilent 86120B Multi Wavelength Meter.
Agilent 86120B Multi‑Wavelength Meter – Professional Repair & Calibration Services
The Agilent 86120B Multi-Wavelength Meter is a precision optical instrument widely used in laboratories, production environments, and telecom applications. Over time, internal components such as the motor assembly, calibration memory, and optical path can drift or fail, resulting in system errors or inaccurate wavelength measurements. Our service center provides complete repair, calibration, and refurbishment for the 86120B to restore full performance and measurement accuracy.
After repair, your 86120B is returned fully calibrated with a complete calibration report, calibration label, and all associated measurement data. If calibration cannot be completed due to a hardware fault, we will evaluate the issue and provide a detailed repair quotation before proceeding.
Common Agilent 86120A/B/C Errors Requiring Repair or Calibration
The 86120 series frequently displays motor-related, communication-related, or calibration-related error messages. Our technicians are trained to diagnose and repair all known issues across the 86120A, 86120B, and 86120C models.
- 86120 Error 1 – Bad checksum from motor
- 86120 Error 2 – Motor communication problem
- 86120 Error 3 – Motor not moving
- 86120 Error 4 – Motor index pulse not found
- 86120 Error 5 – Motor chip set initialization failed
- 86120 Error 6 – Motor communication failure
- 86120 Error 7 – Motor not settled
- 86120 Error 8 – Motor did not stop
- 86120 Error 9 – Motor motion error
- 86120 Error 10 – Motor position limit failed
- 86120 Error 11 – Motor position wrap failed
- 86120 Error 12 – Power level too high
- 86120 Error 13 – Data download problem
What You Receive With Your Calibration
Depending on the calibration level selected, your Agilent 86120B will be returned with:
- A calibration label with date and due date
- A full calibration certificate
- All calibration data and measurement results
If the unit cannot be successfully calibrated, we will:
- Perform a complete diagnostic evaluation
- Provide a repair quotation for your approval
- Complete the repair and recalibration once approved
Your equipment is returned in verified working condition, ready for use in laboratory, production, or field applications.