Click for more products.
No products were found.
The Jonard OTDR-1500 Professional Multi-Function 1310/1550 nm OTDR combines dual-wavelength Optical Time-Domain Reflectometer testing, graphical event mapping, an optical power meter, optical light source and visual fault locator. Its bright 7-inch colour touchscreen, 32/30 dB dynamic range, Wi-Fi connectivity and expandable storage support efficient FTTx construction, commissioning and maintenance. This professional Jonard fiber tester includes a durable enclosure, kickstand, stylus and protective carrying case for field operation.
The Jonard Professional Multi-Function 1310/1550 nm OTDR is an all-in-one fiber optic testing instrument developed for FTTx construction, access network commissioning, maintenance and troubleshooting. It combines Optical Time-Domain Reflectometer testing, graphical event mapping, an optical power meter, an optical light source and a visual fault locator in one field-ready platform.
The instrument tests G.652 single-mode fiber at 1310 nm and 1550 nm. Its dual-wavelength testing capability allows technicians to view results for both wavelengths simultaneously, helping simplify the evaluation of fiber links and the identification of wavelength-dependent events. A dynamic range of 32 dB at 1310 nm and 30 dB at 1550 nm supports professional testing over distances ranging from 500 metres to 80 kilometres.
A large 7-inch colour LCD touchscreen provides an accessible interface for configuring measurements, examining OTDR traces and reviewing event information. The integrated event map represents detected faults and link events graphically, making test results easier to interpret during installation and troubleshooting.
Product reference: OTDR-1500
| Module | Purpose |
|---|---|
| 1310/1550 nm OTDR Module | Characterizes single-mode fiber links and identifies the distance and loss associated with detected events. |
| 1310/1550 nm Light Source Module | Provides stable optical output for loss testing with a compatible optical power meter. |
| Optical Power Meter Module | Measures optical power over a wavelength range from 1200 to 1650 nm. |
| Visual Fault Locator Module | Provides visible 650 nm output for checking continuity and locating certain fiber faults. |
| Help Module | Provides on-instrument assistance for supported functions and operating procedures. |
The OTDR module supports testing at both 1310 nm and 1550 nm. Dual-wavelength testing allows technicians to examine both wavelengths simultaneously, helping streamline fiber link certification and troubleshooting. Comparing results can assist with identifying events that produce different losses depending on the test wavelength.
The instrument offers a 32 dB dynamic range at 1310 nm and a 30 dB dynamic range at 1550 nm. Its test range extends from 500 metres to 80 kilometres, while selectable pulse widths from 3 ns to 10 µs support testing across short and long fiber links.
An event dead zone of 1.5 metres helps the instrument distinguish closely spaced reflective events. The attenuation dead zone is specified at 8 metres. The OTDR provides up to 256,000 sampling points, a 0.01 dB loss threshold and selectable measurement times from 6 to 180 seconds.
The built-in event map translates OTDR measurement results into graphical representations of detected fiber events. This simplified view helps technicians identify connectors, splices, losses, reflections and faults without relying exclusively on interpretation of the full OTDR trace.
Event mapping can improve efficiency during installation and maintenance because technicians can review the approximate location and nature of an event directly on the instrument. The complete OTDR trace remains available when more detailed analysis is required.
The optical power meter module covers a wavelength range from 1200 to 1650 nm and a power measurement range from -60 to 0 dBm. It provides calibration-point power test uncertainty better than 0.22 dB under the specified conditions of -25 dBm, continuous-wave operation and 1310 or 1550 nm.
The optical power meter is suitable for evaluating optical signal levels and supporting loss measurements when used with a compatible light source. Technicians should select the appropriate wavelength and connector interface before performing a measurement.
The integrated optical light source operates at 1310 nm and 1550 nm, providing an output power of at least -5 dBm under the stated temperature conditions. Available operating modes include continuous wave, 270 Hz, 1 kHz and 2 kHz.
The light source can be used with a compatible optical power meter to evaluate insertion loss across a fiber link. Modulated output also assists compatible power meters with source identification during testing.
The visual fault locator operates at 650 nm ±20 nm with a typical output power of at least 2 mW. Available operating modes include continuous wave, 1 Hz and 2 Hz.
Visible red output can assist technicians with continuity checks and the identification of certain breaks, excessive bends or connection problems in accessible fiber links. The VFL uses a TOSA interface. Appropriate laser safety procedures must be followed whenever the visual fault locator is active.
The bright 7-inch colour touchscreen provides a large viewing area for traces, event maps, settings and measurement results. The supplied stylus supports accurate touchscreen navigation while helping keep fingerprints away from the display.
The instrument contains 200 MB of internal storage and can retain up to 4,800 entries. A MicroSD/TF card slot allows users to add external storage. Measurement data is saved using the SOR standard OTDR file format, supporting transfer and review with compatible software.
Built-in Wi-Fi provides options for transferring measurement data and viewing live information with compatible Android devices. A Micro-USB connection is also available for computer data transfer and instrument charging.
These connectivity options help technicians move test results from the field to compatible data management systems. Network compatibility, software requirements and available functions should be verified before deployment.
The instrument is housed in a rubberized hard-plastic enclosure designed for demanding field environments. A built-in kickstand positions the screen for workbench or field viewing, while the protective carrying case and adjustable shoulder strap support transportation between job sites.
The rechargeable lithium-ion battery provides portable power for testing away from an electrical outlet. Dimensions are approximately 33.02 × 10.16 × 10.16 cm, and the stated instrument weight is approximately 2.85 kg.
| Specification | Details |
|---|---|
| Brand | Jonard Tools |
| Product Reference | OTDR-1500 |
| Product Type | Professional Multi-Function Optical Time-Domain Reflectometer |
| OTDR Wavelengths | 1310 nm ±20 nm and 1550 nm |
| Fiber Type | G.652 single-mode fiber |
| Dynamic Range | 32 dB at 1310 nm / 30 dB at 1550 nm |
| Test Range | 500 m to 80 km |
| Event Dead Zone | 1.5 m |
| Attenuation Dead Zone | 8 m |
| Pulse Width | 3 ns to 10 µs |
| Distance Accuracy | ±(0.75 m + sampling interval + 0.0025% × test distance) |
| Loss Accuracy | ±0.02 dB/km |
| Sampling Points | 256K |
| Sampling Resolution | 0.04 to 5 |
| Loss Threshold | 0.01 dB |
| Measurement Time | 6 to 180 seconds |
| Typical Real-Time Refresh Rate | 4 Hz |
| Reflection Accuracy | ±2 dB |
| Stable Source Output Power | -5 dBm |
| Internal Storage | 200 MB, up to 4,800 entries |
| External Storage | MicroSD/TF card |
| File Format | SOR standard file format |
| Included OTDR Connector Adapters | FC and SC/APC |
| Display | 7-inch colour LCD touchscreen |
| Connectivity | Wi-Fi and Micro-USB |
| Dimensions | 33.02 × 10.16 × 10.16 cm |
| Weight | Approximately 2.85 kg |
| UPC | 810053352113 |
| Specification | Details |
|---|---|
| Wavelength Range | 1200 to 1650 nm |
| Power Range | -60 to 0 dBm |
| Calibration-Point Power Test Uncertainty | Better than 0.22 dB at -25 dBm, CW, 1310/1550 nm |
| General Uncertainty | ±5% at -25 dBm, CW |
| Optical Path Power Measurement Uncertainty | Better than ±1.5 dB |
| Specification | Details |
|---|---|
| Output Wavelengths | 1310 nm and 1550 nm |
| Output Power | At least -5 dBm at 23°C ±2°C |
| Operating Modes | CW, 270 Hz, 1 kHz and 2 kHz |
| Specification | Details |
|---|---|
| Centre Wavelength | 650 nm ±20 nm |
| Typical Output Power | At least 2 mW |
| Operating Modes | CW, 1 Hz and 2 Hz |
| Interface Type | TOSA |
Laser safety notice: Never look directly into an active fiber, optical connector or laser output. Verify that the correct connector adapter and test settings are selected before connecting a fiber. Follow all applicable laser safety procedures and the manufacturer's operating instructions.
The Jonard Professional Multi-Function 1310/1550 nm OTDR combines high dynamic range, dual-wavelength measurements, graphical event analysis and integrated optical testing functions in a field-ready instrument. Its large touchscreen, Wi-Fi connectivity, expandable storage and professional measurement capabilities make it suitable for fiber network installation, certification, troubleshooting and maintenance.
Please sign in first.