AFL Noyes OPM5 Optical Power Meter with Data Storage provides professional optical power and loss measurements for single-mode and multimode fiber networks. Wave ID detects up to three wavelengths simultaneously from compatible AFL sources, while internal storage, USB transfer, and TRM 2.0 software support organized results, Pass/Fail analysis, and reporting. OPM5-2D, OPM5-3D, and high-power OPM5-4D detector options are available. Simbol Test Systems is an authorized Canadian distributor and service center for AFL Noyes.
The AFL Noyes OPM5 Optical Power Meter with Data Storage is a rugged handheld instrument for measuring optical power and link loss in single-mode and multimode fiber networks. Available with filtered InGaAs, InGaAs, or germanium detectors, the OPM5 supports applications ranging from premises LAN/WAN testing to telecommunications, Passive Optical Networks, CATV, and DWDM systems.
The OPM5 stores optical references at each calibrated wavelength and organizes test results into multiple files. Stored results can be transferred through USB to AFL TRM 2.0 software for analysis, Pass/Fail evaluation, reporting, and printing. This provides technicians with a practical method for documenting optical loss measurements and demonstrating compliance with applicable network limits.
When paired with a compatible AFL Wave ID optical light source, the OPM5 can identify up to three transmitted wavelengths simultaneously. The meter automatically detects the incoming encoded wavelengths and applies the corresponding calibration settings, helping reduce test time and wavelength-selection errors.
The OPM5-4D uses a filtered InGaAs detector and provides a measurement range from +26 to -50 dBm. It is intended for higher-power applications such as CATV broadband, Passive Optical Networks, and DWDM systems.
The OPM5-3D uses an InGaAs detector with a measurement range from +10 to -75 dBm. Its broad dynamic range is suitable for telecommunications and general single-mode network testing.
The OPM5-2D uses a germanium detector and provides a measurement range from +6 to -60 dBm. It supports premises LAN/WAN applications involving compatible single-mode or multimode fiber networks.
Measurements can be displayed in dB, dBm, or µW with a resolution of 0.01 dB. Typical accuracy is ±0.1 dB, with a specified accuracy of ±0.25 dB under documented conditions.
The OPM5 stores test data for transfer to TRM 2.0 software. Technicians can use the software to analyze results, organize project files, generate network Pass/Fail results, illustrate available system headroom, and prepare professional reports.
The OPM5 includes the TRM 2.0 Basic License. A compatible USB-A to USB Mini-B cable connects the power meter to a computer and can also provide external power when connected to a suitable USB power source.
The AFL Noyes OPM5 is designed for outside-plant, telecom, enterprise, data center, and field-service environments. The housing is engineered to withstand a one-metre drop, while splash-resistant controls support operation in demanding locations and can be used while wearing gloves.
The meter operates from two standard AA batteries and provides approximately 300 hours of battery life. A five-minute automatic shutoff function helps conserve power. The instrument can also accept power from a standard Mini-USB power adapter.
| Model | Detector | Measurement Range | Calibrated Wavelengths | Typical Application |
|---|---|---|---|---|
| OPM5-4D | Filtered InGaAs | +26 to -50 dBm | 850, 980, 1300, 1310, 1490, 1550, and 1625 nm | High-power CATV, PON, broadband, and DWDM systems |
| OPM5-3D | InGaAs | +10 to -75 dBm | 850, 1300, 1310, 1490, 1550, and 1625 nm | Telecommunications and single-mode networks |
| OPM5-2D | Germanium | +6 to -60 dBm | 850, 1300, 1310, 1490, and 1550 nm | Premises LAN/WAN multimode and single-mode networks |
| Brand | AFL Noyes |
| Product Series | OPM5 |
| Product Type | Optical power meter with data storage and reporting support |
| Measurement Units | dB, dBm, and µW |
| Resolution | 0.01 dB |
| Accuracy | ±0.1 dB typical; ±0.25 dB specified |
| Wave ID | Detects up to three wavelengths simultaneously from compatible AFL sources |
| Data Transfer | USB Mini-B connection |
| Software | AFL TRM 2.0 Basic License |
| Adapter Options | FC, SC, ST, LC, 1.25 mm universal, and 2.5 mm universal |
| Power | Two AA batteries or compatible Mini-USB power source |
| Battery Life | Approximately 300 hours |
| Operating Temperature | -10°C to +50°C, up to 95% RH, non-condensing |
| Storage Temperature | -30°C to +60°C, up to 95% RH, non-condensing |
| Dimensions | 14.0 x 8.1 x 3.8 cm |
| Weight | Approximately 0.26 kg |
| Warranty | Five years |
| Adapter | Application | AFL No. |
|---|---|---|
| 2.5 mm Universal | Accepts FC, SC, and ST ferrules | 8800-00-0214 |
| 1.25 mm Universal | Accepts LC and MU ferrules | 8800-00-0224 |
| FC | Threaded FC connector adapter | 8800-00-0200 |
| SC | SC connector adapter | 8800-00-0209 |
| ST | ST connector adapter | 8800-00-0202 |
| LC Simplex | LC simplex connector adapter | 8800-00-0225 |
| E-2000 | E-2000 connector adapter | 8800-00-0221 |
| 2.5 mm Open Universal | Accepts SC duplex and OptiTap connectors for optical power measurement | 8800-00-0219 |
| SMA | SMA connector adapter | 8800-00-0203 |
| D4 | D4 connector adapter | 8800-00-0201 |
| Biconic | Biconic connector adapter | 8800-00-0204 |
Each OPM5 configuration includes the optical power meter, two AA batteries, a protective rubber boot, one customer-selected adapter cap, a carrying case, and the TRM 2.0 Basic License. The detector type and connector adapter must be selected when ordering.
Simbol Test Systems supplies optical power meters, light sources, Optical Loss Test Sets, Optical Time-Domain Reflectometers, test cords, connector adapters, inspection systems, and fiber optic cleaning products.
Simbol is an authorized Canadian distributor and service center for AFL Noyes, supporting customers who require qualified service for AFL and Noyes optical test products. Support is available for model selection, calibration, repair, maintenance, and technical service.
Periodic calibration helps maintain confidence in optical power and loss measurements. Connector adapters and detector ports should also be inspected and cleaned regularly to reduce contamination-related measurement errors.
Contact Simbol Test Systems with the required detector type, measurement range, wavelengths, connector adapter, and application details to request OPM5 availability, configuration assistance, professional in-lab calibration, repair evaluation, or technical support.
Please sign in first.
Sign in