Click for more products.
No products were found.
Fujikura ELCT2-12 Fusion Splicer Replacement Electrodes are supplied as a matched pair for compatible Fujikura compact fusion splicers, including selected FSM-11S, FSM-11R, FSM-12S, FSM-12R, 21S, and 22S models. Proper installation, electrode stabilization, and arc calibration help maintain controlled arc discharge and consistent fiber heating. Available from Simbol Test Systems, an authorized Canadian distributor and service center for AFL and Fujikura products.
Fujikura ELCT2-12 Fusion Splicer Replacement Electrodes are consumable replacement components for compatible Fujikura compact fusion splicers. Supplied as a matched pair, the electrodes generate the controlled electrical arc used to heat and fuse prepared optical fiber end-faces.
The ELCT2-12 electrode pair is compatible with selected Fujikura FSM-11S, FSM-11R, FSM-12S, FSM-12R, 21S, and 22S fusion splicers. Compatibility should always be verified using the complete splicer model and existing electrode designation before ordering.
The Fujikura ELCT2-12 electrode pair is commonly specified for selected models in the following compact fusion splicer families:
Confirm the complete model number, equipment generation, regional configuration, and existing electrode marking before installing replacement electrodes.
Fusion splicer electrodes operate under repeated high-voltage arc discharges. Each splice contributes to gradual electrode-tip wear. Fiber type, splice mode, arc power, electrode spacing, environmental conditions, and equipment cleanliness can affect electrode condition and service life.
Worn or contaminated electrodes may contribute to unstable arc discharge, unsuccessful arc calibration, inconsistent fiber heating, unusual splice appearance, recurring fusion errors, or changes in estimated splice loss.
The fusion splicer’s electrode counter provides useful maintenance guidance, but splice count should not be the only consideration. Physical electrode condition, calibration results, fusion performance, and the applicable Fujikura maintenance instructions should also be reviewed.
Turn off the fusion splicer before removing or installing electrodes. Follow the applicable Fujikura operating and maintenance instructions, and avoid touching the pointed electrode tips with fingers or tools.
Replace both electrodes together as a matched pair. Combining one new electrode with one worn electrode may create uneven arc geometry and inconsistent fiber heating. Confirm that both electrodes are properly seated and secured before operating the fusion splicer.
After installation, complete the electrode stabilization and arc-calibration procedures specified for the splicer. Use clean, correctly stripped and cleaved fibers during calibration.
Electrode replacement is also an appropriate time to inspect and clean the V-grooves, fiber clamps, mirrors, objective lenses, wind protector, electrode holders, and surrounding fusion chamber.
Simbol Test Systems supplies professional Fujikura fusion splicers, replacement electrodes, V-grooves, fiber holders, cleavers, thermal strippers, batteries, power supplies, cleaning products, and related maintenance parts. As an authorized Canadian distributor and service center for AFL and Fujikura products, we support customers with product selection, repair, maintenance, and technical service.
Electrode compatibility should always be confirmed using the complete fusion splicer model and existing electrode marking. Simbol Test Systems can help identify the correct replacement electrode pair and provide professional in-lab cleaning, electrode installation, arc calibration, maintenance, and repair service.
| Brand | Fujikura |
| Model | ELCT2-12 |
| Product Name | Fujikura ELCT2-12 Fusion Splicer Replacement Electrodes |
| Product Type | Replacement fusion splicer electrode pair |
| Supplied Format | Matched pair of electrodes |
| Primary Function | Generates the controlled electrical arc used to fuse prepared optical fibers |
| General Compatibility | Selected Fujikura FSM-11S, FSM-11R, FSM-12S, FSM-12R, 21S, and 22S fusion splicers |
| Installation Requirement | Install according to the applicable Fujikura operating and maintenance instructions |
| Post-Replacement Procedure | Complete the required electrode stabilization and arc calibration |
| Fusion Splicer Family | Compatible Models | Verification Requirement |
|---|---|---|
| FSM-11 Series | FSM-11S and FSM-11R | Confirm the complete model and existing electrode designation |
| FSM-12 Series | FSM-12S and FSM-12R | Confirm the complete model and equipment generation |
| 21S Series | Fujikura 21S | Confirm the model label and installed electrode type |
| 22S Series | Fujikura 22S | Confirm the model label and installed electrode type |
Contact Simbol Test Systems with the complete Fujikura fusion splicer model, existing electrode marking, splice count, and a brief description of any operating issue to request ELCT2-12 availability, compatibility assistance, electrode replacement, cleaning, arc calibration, maintenance, repair, or technical support.