Fujikura ELCT2-20A Fusion Splicer Replacement Electrodes

Fujikura ELCT2-20A Fusion Splicer Replacement Electrodes are supplied as a matched pair for compatible Fujikura FSM field and ribbon fusion splicers. Replacing worn or contaminated electrodes and completing the required arc calibration help maintain stable arc discharge and consistent fiber heating. Compatibility includes selected FSM-50, FSM-60, FSM-70, and FSM-80 Series models. Available from Simbol Test Systems, an authorized Canadian distributor and service center for AFL and Fujikura products.

Read moreShow less
Condition
New
Reference:
ELCT2-20A
Brand:
Add to compare0
Description

Fujikura ELCT2-20A Fusion Splicer Replacement Electrodes

Fujikura ELCT2-20A Fusion Splicer Replacement Electrodes are consumable replacement components for compatible Fujikura FSM field and ribbon fusion splicers. Supplied as a matched pair, the electrodes generate the controlled electrical arc used to heat and fuse prepared optical fiber end-faces.

Repeated fusion cycles gradually wear the electrode tips and may allow deposits to accumulate around the fusion chamber. Worn, contaminated, damaged, or incorrectly installed electrodes can affect arc stability, fiber heating, arc calibration, estimated splice loss, and overall splice consistency.

The ELCT2-20A is associated with several earlier generations of Fujikura fusion splicers. Because compatibility can vary between single-fiber, ribbon, regional, and Plus models, the complete fusion splicer model should be confirmed before ordering.

Replacement Electrode Pair for Compatible Fujikura Splicers

The Fujikura ELCT2-20A electrode pair is designed to restore the correct electrode configuration in compatible Fujikura fusion splicers. Both electrodes should normally be replaced together to maintain balanced arc geometry and uniform fiber heating.

  • Matched electrode pair: Includes two electrodes for balanced replacement on both sides of the fusion arc.
  • Stable arc performance: Correctly installed electrodes help maintain controlled fiber heating during fusion.
  • Model-specific compatibility: Supports selected Fujikura FSM field and ribbon fusion splicers.
  • Direct replacement: Designed for installation in compatible Fujikura electrode holders.
  • Preventive maintenance component: Electrode inspection and replacement form part of routine fusion splicer maintenance.
  • Arc calibration required: The applicable stabilization and arc-calibration procedures should be completed after installation.
  • Professional service available: Replacement can be combined with fusion-chamber cleaning, inspection, calibration, and functional testing.

Compatible Fujikura Fusion Splicer Models

The Fujikura ELCT2-20A is commonly specified for selected fusion splicers in the following product families:

  • Fujikura FSM-50S and FSM-50R
  • Fujikura FSM-60S and FSM-60R
  • Fujikura FSM-61S and selected FSM-61S+ configurations
  • Fujikura FSM-62S and selected FSM-62S+ configurations
  • Fujikura FSM-70S and FSM-70R
  • Selected Fujikura FSM-70S+ and FSM-70R+ configurations
  • Fujikura FSM-80S and FSM-80C
  • Selected Fujikura FSM-80S+ and FSM-80C+ configurations

This compatibility list is a selection guide rather than a substitute for model verification. Confirm the full splicer model, suffix, existing electrode marking, and applicable service documentation before installing replacement electrodes.

Why Electrode Condition Matters

Fusion splicer electrodes operate under repeated high-voltage electrical discharges. Each fusion cycle contributes to gradual tip wear. Environmental contamination, fiber type, splice mode, electrode gap, arc power, and maintenance practices can also affect electrode condition.

Changes in electrode shape or cleanliness may alter the position, intensity, or stability of the fusion arc. This can contribute to unsuccessful arc calibration, inconsistent fiber heating, unusual splice appearance, recurring fusion errors, or changes in estimated splice loss.

The fusion splicer’s electrode counter provides useful maintenance guidance, but the splice count should not be the only consideration. Physical electrode condition, calibration results, fusion performance, and the applicable Fujikura maintenance instructions should also be reviewed.

Electrode Replacement Procedure

Turn off the fusion splicer before removing or installing electrodes. Follow the model-specific Fujikura operating and maintenance instructions, and avoid touching the pointed electrode tips with fingers or tools.

Replace both electrodes as a matched pair. Combining a new electrode with a worn electrode may create uneven arc geometry and inconsistent fiber heating. Confirm that both electrodes are correctly seated, aligned, and secured before operating the splicer.

After installation, complete the electrode stabilization and arc-calibration procedures specified for the fusion splicer. Use clean, correctly stripped and cleaved fibers during calibration.

Electrode replacement is also an appropriate time to inspect and clean the V-grooves, fiber clamps, mirrors, objective lenses, wind protector, and fusion chamber. Contamination in these areas can cause alignment or fusion problems that may resemble electrode wear.

Signs That Electrode Maintenance May Be Required

  • Repeated arc-calibration failures
  • Unstable or visibly inconsistent fusion arcs
  • Electrode maintenance or replacement notifications
  • Visible contamination, pitting, or damage on the electrode tips
  • Unexpected changes in estimated splice loss
  • Inconsistent fiber heating or unusual splice appearance
  • Recurring splice errors after fiber preparation has been verified
  • Electrode count reaching the maintenance interval specified for the splicer

Why Buy Fujikura ELCT2-20A Electrodes from Simbol Test Systems?

Simbol Test Systems supplies professional Fujikura fusion splicers, replacement electrodes, V-grooves, fiber holders, cleavers, thermal strippers, batteries, power supplies, cleaning products, and related maintenance parts. As an authorized Canadian distributor and service center for AFL and Fujikura products, we support customers with product selection, repair, maintenance, and technical service.

Electrode compatibility should always be verified using the complete fusion splicer model and existing electrode marking. Simbol Test Systems can help confirm whether the ELCT2-20A is appropriate and provide professional in-lab electrode replacement, cleaning, arc calibration, maintenance, and repair service.

Fujikura ELCT2-20A Product Information

Brand Fujikura
Model ELCT2-20A
Product Name Fujikura ELCT2-20A Fusion Splicer Replacement Electrodes
Product Type Replacement fusion splicer electrode pair
Supplied Format Matched pair of electrodes
Primary Function Generates the controlled electrical arc used to fuse prepared optical fibers
General Compatibility Selected Fujikura FSM-50, FSM-60, FSM-70, and FSM-80 Series field and ribbon fusion splicers
Installation Requirement Install according to the applicable Fujikura operating and maintenance instructions
Post-Replacement Procedure Complete the required electrode stabilization and arc calibration
Supplier and Support Simbol Test Systems

 

Compatibility Guide

Fusion Splicer Family Example Models Verification Required
FSM-50 Series FSM-50S and FSM-50R Confirm complete model and existing electrode marking
FSM-60 Series FSM-60S, FSM-60R, FSM-61S, and FSM-62S Confirm model suffix and hardware generation
FSM-70 Series FSM-70S and FSM-70R Confirm standard or Plus configuration
FSM-80 Series FSM-80S and FSM-80C Confirm standard or Plus configuration

 

Professional Maintenance and Technical Support

Contact Simbol Test Systems with the complete Fujikura fusion splicer model, current electrode marking, splice count, and description of any operating issue to request ELCT2-20A availability, compatibility assistance, electrode replacement, cleaning, arc calibration, maintenance, repair, or technical support.

Read moreShow less
Product Details
ELCT2-20A

Menu

Share

Cookie consent