Click for more products.
No products were found.
Fujikura ELCT2-25 Fusion Splicer Replacement Electrodes are supplied as a matched pair for compatible Fujikura ARCMaster and specialty fusion splicers, including the FSM-100M and FSM-100P. Replacing worn or contaminated electrodes and completing the required stabilization and arc-calibration procedures help maintain controlled plasma-zone performance and consistent fiber heating. Available from Simbol Test Systems, an authorized Canadian distributor and service center for AFL and Fujikura products.
Fujikura ELCT2-25 Fusion Splicer Replacement Electrodes are consumable components designed for compatible Fujikura ARCMaster and specialty fiber fusion splicers. Supplied as a matched pair, the electrodes generate the controlled electrical arc used to heat and fuse prepared optical fiber end-faces.
The ELCT2-25 electrodes are specified for compatible Fujikura FSM-100M and FSM-100P specialty fusion splicers. They may also support selected legacy specialty splicers, but compatibility should always be verified using the complete equipment model and existing electrode part number.
Electrode condition is important for maintaining stable plasma-zone performance. Repeated arc discharges gradually wear the electrode tips and can allow deposits to accumulate in the fusion chamber. Worn, contaminated, damaged, or incorrectly installed electrodes may affect arc calibration, fiber heating, estimated splice loss, and process consistency.
The Fujikura ELCT2-25 electrode pair is designed to match the electrode geometry, mounting arrangement, and plasma-zone requirements of compatible specialty fusion splicers.
Fusion splicer electrodes operate under repeated high-voltage arc discharges. Each discharge contributes to gradual electrode-tip wear. Arc power, electrode spacing, fiber diameter, splice mode, environmental conditions, and equipment cleanliness can all affect electrode life.
Changes in electrode geometry or surface condition may alter the shape, location, or stability of the plasma zone. This can contribute to inconsistent fiber heating, unsuccessful arc calibration, unusual splice appearance, or changes in estimated splice loss.
The fusion splicer’s arc count provides useful maintenance guidance, but the physical condition of the electrodes and actual fusion performance should also be reviewed. Electrode replacement may be required earlier when processing large-diameter fibers or operating under demanding laboratory or production conditions.
The ELCT2-25 electrode pair is specified for the following Fujikura ARCMaster specialty fusion splicers:
The ELCT2-25 may also be associated with selected legacy Fujikura specialty splicers, including certain FSM-45PM and large-diameter fiber configurations. Verify the complete splicer model, suffix, installed electrode type, and applicable maintenance documentation before ordering.
The ELCT2-25 should not be substituted for ELCT3-25 or ELCT3-25-LDF electrodes used with compatible FSM-100M+ and FSM-100P+ systems.
Turn off the fusion splicer before removing or installing electrodes. Follow the applicable Fujikura operating and maintenance instructions, and avoid touching the electrode tips with fingers or tools.
Replace both electrodes together as a matched pair. Combining a new electrode with a worn electrode may create uneven arc geometry and inconsistent fiber heating. Confirm that both electrodes are properly seated and secured before operating the splicer.
After installation, complete the electrode stabilization and arc-calibration procedures required for the specific fusion splicer and fiber application. Use clean, correctly prepared fibers during calibration.
Electrode replacement is also an appropriate time to inspect and clean the V-grooves, fiber clamps, mirrors, objective lenses, electrode holders, and surrounding fusion chamber.
Simbol Test Systems supplies professional Fujikura ARCMaster fusion splicers, replacement electrodes, fiber holders, precision cleavers, thermal strippers, ultrasonic cleaners, and related specialty fiber preparation equipment. As an authorized Canadian distributor and service center for AFL and Fujikura products, we support customers with product selection, repair, maintenance, and technical service.
Electrode compatibility should be confirmed using the complete fusion splicer model and existing electrode marking. Simbol Test Systems can help verify the correct replacement electrodes and provide professional in-lab cleaning, electrode installation, arc calibration, maintenance, and repair service.
| Brand | Fujikura |
| Model | ELCT2-25 |
| Product Name | Fujikura ELCT2-25 Fusion Splicer Replacement Electrodes |
| Product Type | Specialty fusion splicer replacement electrode pair |
| Supplied Format | Matched pair of electrodes |
| Primary Function | Generates the controlled electrical arc used for specialty optical fiber fusion |
| Primary Compatibility | Fujikura ARCMaster FSM-100M and FSM-100P |
| Additional Compatibility | Selected legacy Fujikura specialty fusion splicers, subject to model verification |
| Installation Requirement | Install according to the applicable Fujikura operating and maintenance instructions |
| Post-Replacement Procedure | Complete the required electrode stabilization and arc calibration |
| AFL No. | S002068 |
| Supplier and Support | Simbol Test Systems |
| Description | General Compatibility | AFL No. |
|---|---|---|
| Fujikura ELCT2-25 Replacement Electrodes, pair | Compatible Fujikura FSM-100M and FSM-100P ARCMaster specialty fusion splicers | S002068 |
Select the ELCT2-25 for compatible Fujikura FSM-100M and FSM-100P specialty fusion splicers. For FSM-100M+ or FSM-100P+ systems, confirm whether ELCT3-25 standard electrodes or ELCT3-25-LDF large-diameter fiber electrodes are required.
For legacy Fujikura FSM-45PM or other specialty fusion splicers, provide the complete model number and existing electrode marking before ordering.
Contact Simbol Test Systems with the complete Fujikura fusion splicer model, current electrode marking, arc count, fiber dimensions, and description of any operating issue to request ELCT2-25 availability, compatibility assistance, electrode installation, cleaning, arc calibration, maintenance, repair, or technical support.
Please sign in first.
Sign in