Click for more products.
No products were found.
Fujikura Fusion Splicer Replacement Electrodes are matched electrode pairs for compatible Fujikura field, ribbon, and ARCMaster specialty fusion splicers. Available models support standard telecom fiber, mass fusion splicing, specialty fiber, and large-diameter fiber processing. Correct electrode selection, installation, stabilization, and arc calibration help maintain reliable discharge performance and consistent fiber heating. Available from Simbol Test Systems, an authorized Canadian distributor and service center for AFL and Fujikura products.
Fujikura Fusion Splicer Replacement Electrodes are consumable components designed for compatible Fujikura field, ribbon, and specialty fiber fusion splicers. Installed as a matched pair, the electrodes create the controlled electrical arc used to heat and fuse prepared optical fiber end-faces.
Electrode condition is important for maintaining stable arc discharge and consistent fiber heating. Repeated fusion cycles gradually wear the electrode tips and can allow deposits to accumulate in the fusion chamber. Worn, contaminated, damaged, or incorrectly installed electrodes may affect arc calibration, estimated splice loss, fusion consistency, and overall splice quality.
Fujikura produces several electrode models for different fusion-splicer platforms. Standard field-splicer electrodes, ribbon-splicer electrodes, ARCMaster specialty electrodes, and large-diameter fiber electrodes are not necessarily interchangeable. Always confirm the complete fusion-splicer model and required electrode part number before ordering.
Fujikura electrodes are designed to match the mounting arrangement, electrode geometry, spacing, and arc requirements of compatible splicers. Replacing worn electrodes with the correct matched pair helps restore the intended discharge characteristics of the fusion system.
Fusion splicer electrodes operate under repeated high-voltage arc discharges. Each splice contributes to gradual tip wear. The actual electrode service life depends on the splicer model, fiber type, splice mode, arc power, electrode gap, operating environment, cleanliness, and maintenance practices.
As the electrode tips wear, the shape and stability of the fusion arc may change. This can contribute to inconsistent fiber heating, failed arc calibration, unusual splice appearance, increased estimated splice loss, or recurring fusion errors.
The splicer’s electrode counter provides useful maintenance guidance, but splice count should not be the only consideration. The physical electrode condition, arc-calibration results, fusion performance, and applicable Fujikura maintenance instructions should also be reviewed.
The ELCT2-16B electrode pair, AFL No. S017103, is used with selected Fujikura 90 Series, 31/41S, and 35/45S fusion splicers. Compatibility must be verified using the complete splicer model because requirements can vary between product generations.
The ELCT2-16C electrode pair, AFL No. S018669, is specified for compatible Fujikura 100S and 100R fusion splicers. It should not be replaced with another ELCT model unless compatibility has been confirmed.
Legacy Fujikura fusion splicers and models not listed on this page may require another electrode type. Provide the complete model number and current electrode part number when requesting replacements.
The ELCT2-25 electrode pair is intended for selected Fujikura ARCMaster FSM-100M and FSM-100P specialty fusion splicers. These systems use advanced plasma-zone control for specialty optical fibers and require electrodes matched to the arc-processing platform.
The ELCT3-25 is the standard electrode configuration for selected FSM-100M+ and FSM-100P+ ARCMaster systems. The ELCT3-25-LDF is intended for supported large-diameter fiber applications requiring a wider or differently controlled plasma zone.
Standard and large-diameter fiber electrodes should not be substituted without confirming the ARCMaster model, fiber diameter, electrode spacing, processing method, and required operating procedure.
Before replacing electrodes, turn off the fusion splicer and follow the applicable Fujikura operating and maintenance instructions. Avoid touching the electrode tips because oil, dirt, or physical damage can affect arc performance.
Replace both electrodes together as a matched pair. Combining one new electrode with one worn electrode may create uneven arc geometry and inconsistent fiber heating. Confirm that both electrodes are properly seated and secured before operating the splicer.
After installation, complete the electrode stabilization and arc-calibration procedures required for the splicer. The exact process varies by model and should be performed using clean, properly prepared fiber under suitable environmental conditions.
Electrode replacement is also an appropriate time to inspect and clean the V-grooves, fiber clamps, objective lenses, mirrors, wind protector, and fusion chamber. Contamination in these areas may cause alignment or splice-performance problems that resemble electrode wear.
Simbol Test Systems supplies professional Fujikura fusion splicers, replacement electrodes, V-grooves, fiber holders, cleavers, thermal strippers, cleaning kits, batteries, power supplies, and related maintenance parts. As an authorized Canadian distributor and service center for AFL and Fujikura products, we support customers with product selection, repair, maintenance, and technical service.
Electrode compatibility should always be confirmed using the complete fusion-splicer model and existing electrode part number. Simbol Test Systems can help identify the appropriate electrode pair and provide professional in-lab cleaning, electrode replacement, arc calibration, maintenance, and repair services.
| Brand | Fujikura |
| Product Type | Replacement fusion splicer electrodes |
| Supplied Format | Matched electrode pair unless otherwise specified |
| Primary Function | Generates the controlled electrical arc used to heat and fuse prepared optical fibers |
| Applications | Field fusion splicing, mass fusion splicing, specialty fiber processing, and large-diameter fiber processing, depending on electrode model |
| Selection Requirement | Select according to the complete Fujikura fusion-splicer model and hardware configuration |
| Installation Requirement | Install according to the applicable Fujikura operating and maintenance instructions |
| Post-Replacement Procedure | Complete the required electrode stabilization and arc calibration |
| Electrode Model | General Compatibility | AFL No. |
|---|---|---|
| ELCT2-16B | Selected Fujikura 90 Series, 31/41S, and 35/45S fusion splicers | S017103 |
| ELCT2-16C | Compatible Fujikura 100S and 100R fusion splicers | S018669 |
| ELCT2-25 | Selected Fujikura ARCMaster FSM-100M and FSM-100P specialty fusion splicers | S002068 |
| ELCT3-25 | Standard electrodes for selected Fujikura ARCMaster FSM-100M+ and FSM-100P+ fusion splicers | S015184 |
| ELCT3-25-LDF | Large-diameter fiber electrodes for compatible Fujikura ARCMaster Plus specialty fusion splicers | S015015 |
Select ELCT2-16B only for a compatible Fujikura splicer specified for AFL No. S017103. This includes selected 90 Series, 31/41S, and 35/45S fusion splicers.
Select ELCT2-16C for compatible Fujikura 100S and 100R fusion splicers. Confirm the complete equipment model before ordering.
Select ELCT2-25 for compatible FSM-100M and FSM-100P ARCMaster specialty systems. For FSM-100M+ and FSM-100P+, verify whether the application requires standard ELCT3-25 or large-diameter fiber ELCT3-25-LDF electrodes.
For legacy or unlisted Fujikura fusion splicers, provide the complete model number and current electrode marking because another electrode model may be required.
Contact Simbol Test Systems with the complete Fujikura fusion-splicer model, existing electrode model, splice count, fiber application, and description of any operating problem to request replacement electrodes, compatibility assistance, cleaning, electrode installation, arc calibration, maintenance, repair, or technical support.
Please sign in first.
Sign in